ASOCRET-BIS-1/6
Mineral-based fine repair mortar for 1-6 mm voids
- product data sheet
- download data sheet
Properties:
- Impermeable to water
- Water vapour permeable
- Frost fast and resistant to de-icing salts
- Very good working properties
- Application by trowel or spray
- Reduces CO2 penetration
- High resistance to carbonation
Areas of Application:
ASOCRET-BIS-1 /6 is used for horizontal and vertical areas as well as overhead areas as a non-sag fine repair mortar for voids up to max. 6 mm. It is furthermore suitable as a levelling compound for swimming pool tanks and other tanks as well as for forming pool edge details for the subsequent application of bonded waterproof membranes or the installation of tiles.
Storage:
cool and dry, 12 months in the original unopened packaging.
Use opened packaging promptly.
Technical Data:
- Basis: factory blended dry mortar
- Colour: cement grey
- Grain size: up to 0.5 mm
- Pot life*: approx. 60 minutes
- Overcoat after: min. 1 day
- Substrate/application temp: min. +5 °C, max. +30 °C
- Compressive strength: 24 hrs, approx. 16 N/mm2
7 days, approx. 32 N/mm2
28 days, approx. 40 N/mm2 - Flexural strength: 24 hrs, approx. 2 N/mm2
7 days, approx. 7 N/mm2
28 days, approx. 8 N/mm2 - Consumption: approx. 1.6 kg/m2/mm thickness
- Cleaning: Thoroughly clean work tools with water after use
- Packaging:25 kg bag
Product Details
Application by hand
Apply a scratch coat of ASOCRET-BIS-1/6 to the prepared substrate and then lay to the desired thickness. Striking off the mortar is determined by the application involved using a suitable tool (lath, trowel etc} within the pot life. After leaving for the appropriate length of time, the surface can be finished using a feltboard or sponge-board.
Wet spray application
The surface to be treated must be adequately wetted until matt-damp. Re-profiling with wet spray techniques is carried out after mixing in a compulsory mixer with a suitable feed pump using a 12 mm spray reprofiling gun or a 35/12 mm MAWO nozzle. For an even spray pattern a high output construction compressor (min. 4 m3 air / 4-5 bar operating pressure) is a mandatory requirement.
Without compulsory mixer
Pump system: High Comp Power
Pump unit: XP 120
Water demand: approx. 160 – 180 |/hr
Nozzle: MAWO nozzle 35/12 mm or 12 mm re-profiling spray gun
Max. Pipe length: 30 m
Control nozzle displacement: 0.5 – 1.0m