INDUGROUT-EP100
THREE-COMPONENT, SOLVENT-FREE, HIGH-PERFORMANCE, FREE- FLOWING EPOXY GROUT
- product data sheet
- download data sheet
Properties:
INDUGROUT-EP100 is a three-component, solvent- free, non-shrink, high-performance, epoxy-resin, free-flowing grout for gaps of 10 mm to 100 mm. INDUGROUT-EP100 is based on a selection of epoxy resins, curing agents, and hard & inert aggregates that – when mixed – provide a grout of excellent adhesion with high early and final compressive & mechanical strengths, in addition to good chemical resistance.
Application Method:
It is important to make available ample product and ensure a steady & continuous pouring process to prevent air entrapment or pocket formation. Mixing & pouring times per kit should be carefully considered to avoid any discontinuation of any single pour. Rodding or vibrating is not required as INDUGROUT-EP100 is a free-flowing grout. Always place grouts from one side of the base plate only, whilst maintaining a constant „liquid grout“ head until the grout rises at other sides of the base plate. The constant liquid head prevents air pocket formation under the base plate and assures proper adhesion and contact (effective bearing area). Do not apply at thicknesses lower than 10 mm. Do not exceed 100 mm layer thickness in any single application. Refer to the method statement for more details.
Primary Uses :
INDUGROUT-EP100 is typically used to grout:
- Under machinery plates exposed to high.
- Dynamic loads or vibrations.
- Under machinery that will be exposed to.
- Chemical attack.
- Under bridge bearing pads.
- Crane rails.
- High strength anchoring bolts.
- Large area cavities in the concrete.
Technical Data:
- Appearance : free flow grey liquid. .
- Density Pot-:2.0 g/mm3 at 20ºC.
- life:120 minutes at 23ºC.
- Chemical Resistance:reagents & chemicals; including salt water, organic & inorganic acids, alkalis, etc.
- Flash Point:> 200ºC.
- Water absorption (ASTM D-570)0.10%
Product Details
It is essential that there is at least 8 cm
It is essential that there is at least 8 cm coverage of concrete from the side exposed to water. Bond AQUAFIN-CJ6 with a mounting adhesive suitable for waterstops. Completely cover the prepared substrate with the mounting adhesive and press the AQUAFIN-CJ into the adhesive until it oozes out from beneath. Do not begin the concreting process for at least 8 hours after bonding.
Waterstop connections can be made
Waterstop connections can be made by overlapping by 50 mm or by butt jointing. The waterstops must be placed tightly together to prevent gaps. But jointed waterstops must be covered by a separate section of waterstop with a 30 mm overlap to both sections.