SANIFLEX – UNIVERSAL

Elastomeric Waterproofing Coating

Primary Uses:

SANIFLEX-Universal is formulated to be used as a waterproofing, decorative and protective coating in:

  • Protection of atmospherically exposed reinforce concrete
    structures from attack by acid gases, chloride ions, carbon dioxide, oxygen and water.
  • Decorative, protective and waterproof coating against water.
  • As waterproof membrane under or above floor screeds.
  • Swimming pools & flat roof coating.
  • Internal & external waterproofing and damp proofing of concrete and masonry substrates.
  • Sealing and coating tie bar holes for water tightness.

Advantages

  • Easy to apply by suitable brush or roller or airless spray equipment.
  • Excellent adhesion to sound masonry substrates: porous and non-porous.
  • Excellent freeze/thaw resistance.
  • Enables the cement based substrates to breathe while waterproofing.
  • Can be applied on Bituminous substrate as reflective and protective coating
  • Elastomeric with excellent elongation and recovery properties.
  • Decorative; improves surface appearance.
  • Protects against waterborne salts [e.g. chlorides, Sulphate ,etc.), atmospheric gases and carbonation (1.8 mm of the cured film is equivalent to 150 mm of concrete cover).
  • UV resistant.
  • Excellent barrier to carbon dioxide, chloride ions, oxygen and water

Storage:

SANIFLEX-Universal shall be stored innormal conditions away from any extreme temperatures. Shelf life is 12 months
f stored properly in well-closed containers.

Technical Data

  • Appearance: Brushable consistency
  • Solid Content: 67 % by volume
  • Application temperature: 5 – 35 °C
  • Time between re coating: 4-6 hours
  • Density at 20 °C: 1.4kg/liter
  • Water vapor diffusion resistance: SD0.11 m at 400 M DFT
  • Reduction in water penetration (BS 1881 Part 111: 1983): 83%
  • Tensile Strength: 4.11 N/mm2
  • Elongation (ASTM D412-16): 90%
  • Carbon dioxide diffusion resistance Equivalent thickness of air Initial: > 470 meters
  • After 2000 hours QUV: > 470 meters
  • Crack bridging: 1.20 mm
  • Pull-off Strength: 1.82 N/mm2
  • Consumption range : 1 to 2 kg per SQM (minimum 3 coats)

Product Details

Stir SANIFLEX-Universal well before use

Stir SANIFLEX-Universal well before use. Apply SANIFLEX- Universal onto prepared substrates using suitable brush, roller or airless spray equipment for large areas. Apply the second coat after application of the first coat within 6-hours