AQUAFIN® CJ6
Thermoplastic Expansive Waterstop For Waterproofing Construction Joints
- product data sheet
- download data sheet
Properties:
- Simple application
- Rapid and strong expansion
- Self-injecting function into cracks and voids
- Completely dimensionally stable even at high temperatures
- Swelling process inexhaustible, often reversible
- Suitable for fresh water and sea water applications
Areas of Application:
AQUAFIN-CJ6 is used for waterproofing the inner side of concrete construction joints in accordance with Building Regulations list A, part 2, serial number 2.53, where there is constant or intermittent exposure to ground water, run-off water and/or surface water. AQUAFIN-CJ6 is suitable for riparian zones. Construction joints can be sealed watertight to a depth of 8 m.
AQUAFIN-CJ6 is suitable for application class A exposure levels 1 and 2 in accordance with the waterproofing guidelines of the German reinforced concrete commission (* 1).
Storage:
2 years when stored dry, frost free and protected against weathering
Technical Data:
- Basis: TPE (thermoplastic elastomer)
- Colour: red
- Density: approx 1.25g/m3
- Water Contact: 6 hrs
- Packaging: rolls with 40 linear metres = 200 linear metres/ carton
- Format: Waterstop profile is quadratic + flexible
- Thickness: 5 mm
- Width: 20 mm
- Start of swelling on water contact: approx 6 hrs
- Swelling capacity (demineralized water): approx. 50% after 2 hrs
approx. 460% after 24 hrs
> 850% alter 8 days - Water impermeability after installation:
- Joint width 0.25 mm: 2 bar
- Joint width 1.0 mm: 1.5 bar
- Toxicity: none
- Reaction to fire: class E to DIN EN 13501-1
- Packaging: rolls with 40 linear metres = 200 linear metres/
carton
Product Details
It is essential that there is at least 8 cm
It is essential that there is at least 8 cm coverage of concrete from the side exposed to water. Bond AQUAFIN-CJ6 with a mounting adhesive suitable for waterstops. Completely cover the prepared substrate with the mounting adhesive and press the AQUAFIN-CJ into the adhesive until it oozes out from beneath. Do not begin the concreting process for at least 8 hours after bonding.
Waterstop connections can be made
Waterstop connections can be made by overlapping by 50 mm or by butt jointing. The waterstops must be placed tightly together to prevent gaps. But jointed waterstops must be covered by a separate section of waterstop with a 30 mm overlap to both sections.